StatManager™
- An Advanced Test Coverage Report Generator
Acculogic introduces StatManager™ - an advanced test program
coverage report generator with boundary scan fault inject capability.
StatManager can calculate part and pin level coverage of Teradyne
Spectrum™ and Z18XX test programs.
StatManager enables the user to:
- Obtain a detailed coverage report that includes information
on global, sectional and device level coverage as well as a list
of untested components.
- Calculate and analyze pin coverage for digital devices with
multiple tests on overlapping bases as well as individually and
per test type.
- Fault inject Boundary Scan Devices (what is currently impossible
in the Spectrum environment) to obtain complete information on
the efficiency of a test program.
- Generate a report that shows Digital Disable Table/s with a
pin ID and the applied logic signal, and a list of components
tested in parallel.
- Create a report, which lists untested pins per Digital, Bscan
and Fscan device.
StatManager’s optional utilities allow users to reduce time
and errors during the fixture design and test program preparation
stages. These utilities include:
- “IPL formatter” – to check the “IPL.DAT”
file for errors, adding the system tolerance to device tolerances
and necessary tests and power supplies.
- “Unused node extractor” – to get a list of
nodes which may potentially fail during APC test.
- “Net assigner” – to extract and assign nets
for particular devices having different logic levels (fixture
design stage).
Download
sample file
ProgramGuard™
for Teradyne Spectrum 88xx
With ProgramGuard for Spectrum Version 1.0, the user is able to
compare two generated Spectrum ASCII files to catch eventual differences
between them. These files are called ‘Source Program’
and ‘Target Program’. The first file is the ‘Golden’
file and plays the ‘master’ role and the second file
plays the ‘slave’ role.
ProgramGuard is able to distinguish Sections, Steps and Pages inside
both mentioned ASCII files. The sections listed in the ProgramGuard
panel are those that taken from the master file.
After processing the two files and obtaining the results, the differences
between the two files are displayed in the 'Results' box. The following
differences are displayed when detected:
- Running Permission Status for all sections, steps and pages.
- Test vectors and digital patterns.
- Digital-analog test measurements.
- ‘COUNT’, ‘HIGH’ and ‘CRC’
values of digital sections.
- ‘High’ values and ‘Low’ values of passive
and active devices.
- ‘Pin Type’ values in Frame Scan.
The ProgramGuard supervisor can update the master file with any
differences displayed in the results box. This transaction can be
saved as a formatted text report file.
 |